DCAR – Bauer Kompressoren & Ingersoll Rand

Booster

Booster GIB 23 1.330 – 3.500 l/min

GIB series: high-pressure air-cooled booster compressors for the compression of air, nitrogen, helium and argon – designed for the most demanding conditions of use.

Fully automatic compressor control: B-CONTROL II.

Perfect flow rates for every application: for compression of air, nitrogen, helium and argon

BK 23 – BK 52 series compressor blocks: for the simultaneous absorption of internal gas forces.

Minimal installation and maintenance work: a major advantage of air-cooled systems.

Powerful air-cooled system: for compression systems with drive powers up to 110 kW.


The air-cooled booster compressors of the GIB series from BAUER KOMPRESSOREN are characterized by their pressure-resistant housing up to 16 bar. In this way, compression to the desired final pressure is possible without leakage losses.

A powerful air-cooling system with large coolers, in combination with large-area ribbed cylinders, provides perfect cooling of each compression stage.

As economical and long-life system solutions for difficult applications, these multi-stage booster compressors offer a wide range of possibilities: secondary air compressor for the compressed air network, nitrogen compressor for inert gases from generators or storage system combinations, or gas compressor for the compression of methane from pipelines or biogas directly from the treatment plant.

Adapted to individual wishes and industrial requirements, BAUER KOMPRESSOREN also manufactures tailor-made turnkey system solutions.

Medium pressure booster GIB 23, 1330 – 3500 l / min, 90 – 365 bar 4..

DESIGNAÇÃO DE MODELO FLUXO EFETIVO¹ PRESSÃO DE SUCÇÃO PRESSÃO DE CORTE MÍN. | MÁX. ² NÚMERO DE ETAPAS REVOLUÇÕES APROX. POTÊNCIA DO MOTOR CONSUMO DE ENERGIA¹ PESO LÍQUIDO APROX.
L / MIN M³ / H CFM BAR G BAR BAR RPM KW KW KG LIBRAS
GIB 23.10-37  3 1330 80 47 2 90 200 4 1140 37 vinte e um 1150 2535
1780 107 63 3 150 300 29
2220 133 78 4 200 350 36
2440 146 86 4,5 200 350 Quatro cinco 38
GIB 23.12-37 1700 102 60 4,5 90 200 4 1140 37 22 1150 2535
2100 128 74 6 150 300 30
2700 162 95 8 200 350 Quatro cinco 37
3300 198 116 10 200 350 43
GIB 23.13-37  3 2100 126 74 8 150 200 4 1140 37 vinte 1150 2535
2600 156 92 10 150 300 27
3000 180 106 12 200 350 32
3500 210 124 14 200 350 35

¹ Flow rate according to ISO 1217, energy consumption at maximum final pressure under defined frame conditions. Different ambient conditions will cause other performance data. Direct coupled installations: Values valid for 50 Hz.

² Cut-off pressure (end pressure sensor).

³ Suitable with reserves for helium. Requires clarification from BAUER. In part, limitations related to inlet and end pressure apply.

⁴ max. pressure relief valve = max. operating. Low cut-off pressure.

 

FLOW CORRECTION FACTOR
Helium flow rate = air flow rate × 0.8.

 

POWER CONSUMPTION CORRECTION FACTOR
Helium energy consumption = Air energy consumption × 1.06.